Abx Micros 60 User Manual

2 years ago SERVICE MANUAL Dear All, Am looking for a service manual for Horiba ABX Micros 60. May anyone who has it share by sending to: vgmakwinja@medcol.mw Thanks in advance. One type of micros training manual is that which has a technical device. It may help explain 3700 POS MICROS USER MANUAL PROGRAMMING. Our nationwide network of abx micros 60 manual is dedicated to Micros Programming Manual The Micros POS system relies on a database that was programmed specifically for the previous restaurant.

  1. Abx Micros 60 User Manual
  2. Horiba Abx Micros 60
  3. Abx Micros Es 60 User Manual
One moment please...
Not A Member?Sign Up
  • Documents
  • Videos
  • News

Abx Micros 60 User Manual

Abx micros es 60 user manual
DESCRIPTION
8 or 18 fully automated parametersCBC / 3 Part DIFFOpen or Closed Tube

Impedance technology, photometry
Microsampling: Only 10 µL
Smart card based memory storage (optional)
No compressor (stepper motor technology)

FORUMSView All (20)
MicrosAsk a New Question

2

Replies
-frankms123_8300
5 months ago
5 months agoHavingproblem with RDW, Low results

Having problems with low RDW results.RBC 5,09-HGB 15,1-HCT 49,3 MCV 97-MCH 29,7 MCHC 30,66 PLT 230 RDW 2,2.

Reply
-Mkama zebedayo
a year ago
a year agoservicing micro 60 and screen master
i would like to know what can i do to my micro 60 that is giving out high PLT reading that is going up to 22222 sometimes giving DIL.also to my screen master that is giving out a wide range of deviation to a single sample or QC testing sample aslo the failure of QC,How to calibrate this one since it has failed more than fifth times?Reply

2

Replies
-Trelaone
2 years ago
2 years agoSERVICE MANUAL
Dear All,Am looking for a service manual for Horiba ABX Micros 60. May anyone who has it share by sending to: vgmakwinja@medcol.mwThanks in advance.Reply

Horiba Abx Micros 60

SERVICE COMPANIESView All Hematology Analyzer Companies

FEATURES

Measurement methods: Impedance technology, photometry. Liquid valves (without pinching): Reliability and increased precision No compressor (stepper motor): Reliability, less maintenance and noise

Additional Specifications

Abx Micros Es 60 User Manual

Technical
Weight
31 lbs
Power supply
90/240 V - 50/60 Hz - 230 VA.
Dimensions
16.5 in x 14 x 12.5 in (HxWxD).
Printer
Dot matrix.
Throughout
60 samples/hour (on open tube)
55 samples/hour (closed tube)
Data management
Automated smart cards used for QC and patient data storage (optional).
RS 232 output.
Mono-directional connection.
Memory
Last result (with curves) or 78 results (optional smart cards based memory)

Screen

2 lines of 40 alphanumerical characters.
Keyboard
Barcode reader (optional).
Samples
60 samples/hour (open tube)
Parameters (16+2)
CBC Mode (18 parameters): WBC, RBC, HGB, HCT, MCV,*RDW, MCH, MCHC, PLT, MPV, PCT, *PDW, % and # of LYM, MON and GRA
Graphics
LMG histogram, RBC, PLT histograms
Sample-Volume
CBC mode : 10 µL
Stability
24 hours (CBC)
Operating sample mode
Open tube mode with 4 position tube holder (QC, 125 or 500 µL, 3 or 5 mL)
Identification
Patient I.D., Sequence#
Flags
Pathological flags (WBC, RBC, and PLT) normal limits and counting failure flags
* RUO (Research Use Only)